Deye 8–15kW Split-Phase Hybrid Inverter | SG01HP2-US-AM2

Deye SG01HP2-US-AM2 split-phase hybrid inverter for solar and high-voltage lithium battery storage, supplied by Solarayen.

Item Specification
Rated power 8 / 10 / 12 / 15kW
AC output 120/240V split phase; 60Hz
Battery voltage 160–500V
PV tracking 2 MPPT

Inquiry Now

New products

Deye 8–15kW Split-Phase Hybrid Inverter

The Deye SG01HP2-US-AM2 integrates solar generation, battery charging and AC power management for split-phase solar-storage projects. Available power ratings are 8 / 10 / 12 / 15kW. Solarayen supplies the original Deye-branded inverter with model selection support for installers and distributors.

This series uses 160–500V batteries. It requires a compatible high-voltage lithium-ion battery system and cannot be connected directly to a 48V battery. Confirm the exact battery BMS protocol, site electrical supply and destination-country approval before ordering.

Conceptual residential Deye SG01HP2-US-AM2 solar battery installation

Conceptual application illustration. Installation and protection follow the manufacturer instructions and approved system design.

Key Features

  • Two independent MPPTs for flexible PV array design.
  • Battery charging and discharging with six programmable time periods.
  • AC coupling for suitable existing solar installations.
  • Up to 10 compatible inverters in parallel for on-grid and off-grid operation, according to Deye configuration requirements.
  • Generator-supported battery charging for suitable systems.
  • LCD interface for operation and monitoring.
  • Maximum efficiency of 97.6% and MPPT efficiency above 99%.
  • 100% unbalanced output supported, subject to model and system load limits.

Technical Specifications and Model Comparison

The table below follows the current Deye datasheet. Ratings differ by model; PV strings, battery current and AC protection must be checked for the selected power rating.

Model SUN-8K-SG01HP2-US-AM2 SUN-10K-SG01HP2-US-AM2 SUN-12K-SG01HP2-US-AM2 SUN-15K-SG01HP2-US-AM2
Battery Input Data
Battery Type  Lithium-ion
Battery Voltage Range (V) 160-500
Max. Charging/Discharging Current (A) 50
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. PV Access Power (W) 16000 20000 24000 30000
Max. PV Input Power (W) 12000 15000 18000 22500
Max. PV Input Voltage (V) 550
Start-up Voltage (V) 180
MPPT Voltage Range (V)  150-500
Rated PV Input Voltage (V) 380
Max. Operating PV Input Current (A) 26+26
Max. Input Short-Circuit Current (A) 39+39
No. of MPP Trackers/No. of Strings MPP Tracker 2/2+2
AC Input/Output Data
Rated AC Input/Output Active Power (W) 8000 10000 12000 15000
Max. AC Input/Output Apparent Power (VA) 8000 10000 12000 15000
Rated AC Input/Output Current (A) 33.4 41.7 50 62.5
Max. AC Input/Output Current (A) 33.4 41.7 50 62.5
Max. Continuous AC Passthrough (grid to load) (A) 150
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage 120/240  0.85Un-1.1Un  2L+N+PE
Rated Input/Output Grid Frequency/Range(Hz) 60/55-65
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
Integrated DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection,
AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,
Arc Fault CircuitInterrupter (AFCI) (optional), Anti-islanding Protection, DC Switch,
Insulation Impedance Detection, Residual Current Detection
Surge Protection Level TYPE II(DC),TYPE II(AC)
Interface
LCD/LEDDisplay LCD
Communication Interface WIFI, RS485, CAN
General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 2000m
Noise (dB) ≤55
Ingress Protection(IP) Rating TYPE3R
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC),OVC IV(AC)
Cabinet Size (WxHxD mm) 408×678×247 (Excluding Connectors and Brackets)
Weight (kg) 30
Type of Cooling Intelligent Air Cooling
Warranty 5 Years / Up to 10 Years*
*Warranty period varies by installation country. Refer to the Warranty Policy for details.
Grid Regulation IEEE 1547.1,SRD V2.0
Safety / EMC Standard FCC, UL 1741

Cabinet dimensions exclude connectors and mounting brackets. The latest datasheet lists TYPE3R enclosure protection; confirm the supplied version and local installation requirements. Warranty availability depends on installation country and Deye policy.

The gallery cabinet-size schematic uses the latest datasheet dimensions, 408 × 678 × 247mm. The linked earlier manual may show a previous mechanical drawing; confirm the final installation drawing for the supplied hardware.

Rear Construction and Mounting

The original manufacturer rear view helps identify the mounting layout and heat-sink structure.

Deye SG01HP2-US-AM2 original rear construction and mounting view

Controls and Connection Interfaces

The manufacturer overview identifies the LCD, operating controls, battery terminals, PV inputs and grid, load and generator connections. Use the exact manual for terminal identification and installation.

Deye SG01HP2-US-AM2 manufacturer controls and connection ports overview

System Integration

The gallery architecture illustrates PV generation, battery storage, grid, backup loads and optional generator integration. It is a system overview; final cable sizing, protection, earthing and commissioning follow the installation manual.

Frequently Asked Questions

Is this a standard 230V single-phase inverter?

This product is designed for split-phase applications, with 120/240V and 60Hz ratings. Verify the exact supply, configuration and destination-country requirements before ordering.

Can it work with a 51.2V LiFePO4 battery?

No. This model requires a compatible 160–500V high-voltage lithium battery system. A 48V or 51.2V battery must not be connected directly.

Are all power variants identical?

No. The rated output is 8, 10, 12 or 15kW. PV input power and AC current vary by model; all use two MPPTs and a maximum battery charge/discharge current of 50A.

How long can it supply backup power?

Runtime depends on usable battery energy, load demand, battery limits and conversion losses. The inverter kW rating does not determine backup duration.

Can multiple units operate together?

Deye specifies up to 10 compatible units in parallel. Check firmware, communication, battery design and the exact manufacturer parallel wiring instructions.

What information is needed for a quotation?

Send the required power rating, country, grid voltage, battery model and quantity. Solarayen will confirm a suitable configuration, model availability and warranty terms.

Downloads

Deye official datasheet (PDF)

Deye official installation manual (PDF)

Request a Quotation

Contact Solarayen for model availability, compatible battery options and project quotations.

Category

Leave a Message

Tell us what product you need and include the voltage, capacity, quantity or application if available. We will contact you as soon as possible.

Contact Form Demo

Deye 8–15kW Split-Phase Hybrid Inverter

The Deye SG01HP2-US-AM2 integrates solar generation, battery charging and AC power management for split-phase solar-storage projects. Available power ratings are 8 / 10 / 12 / 15kW. Solarayen supplies the original Deye-branded inverter with model selection support for installers and distributors.

This series uses 160–500V batteries. It requires a compatible high-voltage lithium-ion battery system and cannot be connected directly to a 48V battery. Confirm the exact battery BMS protocol, site electrical supply and destination-country approval before ordering.

Conceptual residential Deye SG01HP2-US-AM2 solar battery installation

Conceptual application illustration. Installation and protection follow the manufacturer instructions and approved system design.

Key Features

  • Two independent MPPTs for flexible PV array design.
  • Battery charging and discharging with six programmable time periods.
  • AC coupling for suitable existing solar installations.
  • Up to 10 compatible inverters in parallel for on-grid and off-grid operation, according to Deye configuration requirements.
  • Generator-supported battery charging for suitable systems.
  • LCD interface for operation and monitoring.
  • Maximum efficiency of 97.6% and MPPT efficiency above 99%.
  • 100% unbalanced output supported, subject to model and system load limits.

Technical Specifications and Model Comparison

The table below follows the current Deye datasheet. Ratings differ by model; PV strings, battery current and AC protection must be checked for the selected power rating.

Model SUN-8K-SG01HP2-US-AM2 SUN-10K-SG01HP2-US-AM2 SUN-12K-SG01HP2-US-AM2 SUN-15K-SG01HP2-US-AM2
Battery Input Data
Battery Type  Lithium-ion
Battery Voltage Range (V) 160-500
Max. Charging/Discharging Current (A) 50
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. PV Access Power (W) 16000 20000 24000 30000
Max. PV Input Power (W) 12000 15000 18000 22500
Max. PV Input Voltage (V) 550
Start-up Voltage (V) 180
MPPT Voltage Range (V)  150-500
Rated PV Input Voltage (V) 380
Max. Operating PV Input Current (A) 26+26
Max. Input Short-Circuit Current (A) 39+39
No. of MPP Trackers/No. of Strings MPP Tracker 2/2+2
AC Input/Output Data
Rated AC Input/Output Active Power (W) 8000 10000 12000 15000
Max. AC Input/Output Apparent Power (VA) 8000 10000 12000 15000
Rated AC Input/Output Current (A) 33.4 41.7 50 62.5
Max. AC Input/Output Current (A) 33.4 41.7 50 62.5
Max. Continuous AC Passthrough (grid to load) (A) 150
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage 120/240  0.85Un-1.1Un  2L+N+PE
Rated Input/Output Grid Frequency/Range(Hz) 60/55-65
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
Integrated DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection,
AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,
Arc Fault CircuitInterrupter (AFCI) (optional), Anti-islanding Protection, DC Switch,
Insulation Impedance Detection, Residual Current Detection
Surge Protection Level TYPE II(DC),TYPE II(AC)
Interface
LCD/LEDDisplay LCD
Communication Interface WIFI, RS485, CAN
General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 2000m
Noise (dB) ≤55
Ingress Protection(IP) Rating TYPE3R
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC),OVC IV(AC)
Cabinet Size (WxHxD mm) 408×678×247 (Excluding Connectors and Brackets)
Weight (kg) 30
Type of Cooling Intelligent Air Cooling
Warranty 5 Years / Up to 10 Years*
*Warranty period varies by installation country. Refer to the Warranty Policy for details.
Grid Regulation IEEE 1547.1,SRD V2.0
Safety / EMC Standard FCC, UL 1741

Cabinet dimensions exclude connectors and mounting brackets. The latest datasheet lists TYPE3R enclosure protection; confirm the supplied version and local installation requirements. Warranty availability depends on installation country and Deye policy.

The gallery cabinet-size schematic uses the latest datasheet dimensions, 408 × 678 × 247mm. The linked earlier manual may show a previous mechanical drawing; confirm the final installation drawing for the supplied hardware.

Rear Construction and Mounting

The original manufacturer rear view helps identify the mounting layout and heat-sink structure.

Deye SG01HP2-US-AM2 original rear construction and mounting view

Controls and Connection Interfaces

The manufacturer overview identifies the LCD, operating controls, battery terminals, PV inputs and grid, load and generator connections. Use the exact manual for terminal identification and installation.

Deye SG01HP2-US-AM2 manufacturer controls and connection ports overview

System Integration

The gallery architecture illustrates PV generation, battery storage, grid, backup loads and optional generator integration. It is a system overview; final cable sizing, protection, earthing and commissioning follow the installation manual.

Frequently Asked Questions

Is this a standard 230V single-phase inverter?

This product is designed for split-phase applications, with 120/240V and 60Hz ratings. Verify the exact supply, configuration and destination-country requirements before ordering.

Can it work with a 51.2V LiFePO4 battery?

No. This model requires a compatible 160–500V high-voltage lithium battery system. A 48V or 51.2V battery must not be connected directly.

Are all power variants identical?

No. The rated output is 8, 10, 12 or 15kW. PV input power and AC current vary by model; all use two MPPTs and a maximum battery charge/discharge current of 50A.

How long can it supply backup power?

Runtime depends on usable battery energy, load demand, battery limits and conversion losses. The inverter kW rating does not determine backup duration.

Can multiple units operate together?

Deye specifies up to 10 compatible units in parallel. Check firmware, communication, battery design and the exact manufacturer parallel wiring instructions.

What information is needed for a quotation?

Send the required power rating, country, grid voltage, battery model and quantity. Solarayen will confirm a suitable configuration, model availability and warranty terms.

Downloads

Deye official datasheet (PDF)

Deye official installation manual (PDF)

Request a Quotation

Contact Solarayen for model availability, compatible battery options and project quotations.

Category

Leave a Message

Tell us what product you need and include the voltage, capacity, quantity or application if available. We will contact you as soon as possible.

Contact Form Demo