Deye 5–8kW Split-Phase Hybrid Inverter | SG01LP1-US

Deye SG01LP1-US split-phase hybrid inverter for solar and 48V-class low-voltage battery storage, supplied by Solarayen.

Item Specification
Rated power 5 / 6 / 7.6 / 8kW
AC output 120/240V split phase; 60Hz
Battery voltage 40–60V
PV tracking 2 MPPT

Inquiry Now

New products

Deye 5–8kW Split-Phase Hybrid Inverter

The Deye SG01LP1-US integrates solar generation, battery charging and AC power management for split-phase solar-storage projects. Available power ratings are 5 / 6 / 7.6 / 8kW. Solarayen supplies the original Deye-branded inverter with model selection support for installers and distributors.

This series uses 40–60V batteries. It is a low-voltage, 48V-class platform supporting lead-acid or lithium-ion batteries. Confirm the exact battery BMS protocol, site electrical supply and destination-country approval before ordering.

Conceptual residential Deye SG01LP1-US solar battery installation

Conceptual application illustration. Installation and protection follow the manufacturer instructions and approved system design.

Key Features

  • Two independent MPPTs for flexible PV array design.
  • Battery charging and discharging with six programmable time periods.
  • AC coupling for suitable existing solar installations.
  • Up to 16 compatible inverters in parallel for on-grid and off-grid operation, according to Deye configuration requirements.
  • Generator-supported battery charging for suitable systems.
  • LCD interface for operation and monitoring.
  • Maximum efficiency of 97.6% and MPPT efficiency above 99%.

Technical Specifications and Model Comparison

The table below follows the current Deye datasheet. Ratings differ by model; PV strings, battery current and AC protection must be checked for the selected power rating.

Model SUN-5K-SG01LP1-US SUN-6K-SG01LP1-US SUN-7.6K-SG01LP1-US SUN-8K-SG01LP1-US
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range(V) 40-60
Max. Charging/Discharging Current(A) 120 135 190 190
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. PV Input Power(W) 6500 7800 9880 10400
Max. PV Input Voltage(V) 500
Start-up Voltage(V) 125
MPPT Voltage Range(V) 150-425
Rated PV Input Voltage(V) 370
Max. Operating PV Input Current(A) 13+13 26+13 26+26
Max. Input Short-Circuit Current(A) 22+22 44+22 44+44
No.of MPP Trackers/No.of Strings MPP Tracker 2/1+1 2/2+1 2/2+2
AC Input/Output Data
Rated AC Input/Output Active Power(W) 5000 6000 7600 8000
Max. AC Input/Output Apparent Power (VA) 5500 6600 8360 8800
Rated AC Input/Output Current(A) 20.8 25 31.7 33.3
Max. AC Input/Output Current(A) 22.9 27.5 34.8 36.7
Max. Continuous AC Passthrough (grid to load)(A) 40 50
Peak Power (off-grid)(W) 2 times of rated power,10s
Power Factor Adjustment Range 0.8 leading to 0.8lagging
Rated Input/Output Voltage 120/240; 208  0.88Un< U< 1.1Un  2L+N+PE
Rated Input/Output Grid Frequency/Range(Hz) 60/55-65
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
Integrated DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection,
AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,
Arc Fault CircuitInterrupter (AFCI) (optional), Anti-islanding Protection, DC Switch,
Insulation Impedance Detection, Residual Current Detection
Surge Protection Level TYPE II(DC),TYPE II(AC)
Interface
LCD/LED Display LCD
Communication Interface WIFI,RS485
General Data
Operating Temperature Range(℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0~100%
Permissible Altitude 2000m
Noise(dB) ≤30
Ingress Protection(IP) Rating TYPE3R
Inverter Topology Non-Isolated (solar), Isolated (battery)
Over Voltage Category OVC II(DC),OVC IV(AC)
Cabinet size(WxHxD mm) 420×670×233 (Excluding Connectors and Brackets)
Weight(kg) 30
Type Of Cooling Intelligent Air Cooling
Warranty 5 Years / Up to 10 Years*
*Warranty period varies by installation country. Refer to the Warranty Policy for details.
Grid Regulation EN 50549,UNE 217002,NRS 097,IEEE 1547.1,SRD V2.0
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Cabinet dimensions exclude connectors and mounting brackets. The latest datasheet lists TYPE3R enclosure protection; confirm the supplied version and local installation requirements. Warranty availability depends on installation country and Deye policy.

Rear Construction and Mounting

The original manufacturer rear view helps identify the mounting layout. Keep service access and ventilation clearances available.

Deye SG01LP1-US original rear construction and mounting view

Controls and Connection Interfaces

The manufacturer overview identifies the LCD, operating controls, battery terminals, PV inputs and grid, load and generator connections. Use the exact manual for terminal identification and installation.

Deye SG01LP1-US manufacturer controls and connection ports overview

System Integration

The gallery architecture illustrates PV generation, battery storage, grid, backup loads and optional generator integration. It is a system overview; final cable sizing, protection, earthing and commissioning follow the installation manual.

Frequently Asked Questions

Is this a standard 230V single-phase inverter?

This product is designed for split-phase applications, with 120/240V and 60Hz ratings. Verify the exact supply, configuration and destination-country requirements before ordering.

Can it work with a 51.2V LiFePO4 battery?

51.2V is within the 40–60V operating range. Confirm battery BMS communication, firmware, charge/discharge current and usable capacity before pairing.

Are all power variants identical?

No. Battery current is 120A, 135A, 190A and 190A for 5, 6, 7.6 and 8kW respectively. PV string inputs are 1+1, 2+1, 2+2 and 2+2; passthrough is 40A for 5/6kW and 50A for 7.6/8kW.

How long can it supply backup power?

Runtime depends on usable battery energy, load demand, battery limits and conversion losses. The inverter kW rating does not determine backup duration.

Can multiple units operate together?

Deye specifies up to 16 compatible units in parallel. Check firmware, communication, battery design and the exact manufacturer parallel wiring instructions.

What information is needed for a quotation?

Send the required power rating, country, grid voltage, battery model and quantity. Solarayen will confirm a suitable configuration, model availability and warranty terms.

Downloads

Deye official datasheet (PDF)

Deye official installation manual (PDF)

Request a Quotation

Contact Solarayen for model availability, compatible battery options and project quotations.

Category

Leave a Message

Tell us what product you need and include the voltage, capacity, quantity or application if available. We will contact you as soon as possible.

Contact Form Demo

Deye 5–8kW Split-Phase Hybrid Inverter

The Deye SG01LP1-US integrates solar generation, battery charging and AC power management for split-phase solar-storage projects. Available power ratings are 5 / 6 / 7.6 / 8kW. Solarayen supplies the original Deye-branded inverter with model selection support for installers and distributors.

This series uses 40–60V batteries. It is a low-voltage, 48V-class platform supporting lead-acid or lithium-ion batteries. Confirm the exact battery BMS protocol, site electrical supply and destination-country approval before ordering.

Conceptual residential Deye SG01LP1-US solar battery installation

Conceptual application illustration. Installation and protection follow the manufacturer instructions and approved system design.

Key Features

  • Two independent MPPTs for flexible PV array design.
  • Battery charging and discharging with six programmable time periods.
  • AC coupling for suitable existing solar installations.
  • Up to 16 compatible inverters in parallel for on-grid and off-grid operation, according to Deye configuration requirements.
  • Generator-supported battery charging for suitable systems.
  • LCD interface for operation and monitoring.
  • Maximum efficiency of 97.6% and MPPT efficiency above 99%.

Technical Specifications and Model Comparison

The table below follows the current Deye datasheet. Ratings differ by model; PV strings, battery current and AC protection must be checked for the selected power rating.

Model SUN-5K-SG01LP1-US SUN-6K-SG01LP1-US SUN-7.6K-SG01LP1-US SUN-8K-SG01LP1-US
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range(V) 40-60
Max. Charging/Discharging Current(A) 120 135 190 190
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. PV Input Power(W) 6500 7800 9880 10400
Max. PV Input Voltage(V) 500
Start-up Voltage(V) 125
MPPT Voltage Range(V) 150-425
Rated PV Input Voltage(V) 370
Max. Operating PV Input Current(A) 13+13 26+13 26+26
Max. Input Short-Circuit Current(A) 22+22 44+22 44+44
No.of MPP Trackers/No.of Strings MPP Tracker 2/1+1 2/2+1 2/2+2
AC Input/Output Data
Rated AC Input/Output Active Power(W) 5000 6000 7600 8000
Max. AC Input/Output Apparent Power (VA) 5500 6600 8360 8800
Rated AC Input/Output Current(A) 20.8 25 31.7 33.3
Max. AC Input/Output Current(A) 22.9 27.5 34.8 36.7
Max. Continuous AC Passthrough (grid to load)(A) 40 50
Peak Power (off-grid)(W) 2 times of rated power,10s
Power Factor Adjustment Range 0.8 leading to 0.8lagging
Rated Input/Output Voltage 120/240; 208  0.88Un< U< 1.1Un  2L+N+PE
Rated Input/Output Grid Frequency/Range(Hz) 60/55-65
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
Integrated DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection,
AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,
Arc Fault CircuitInterrupter (AFCI) (optional), Anti-islanding Protection, DC Switch,
Insulation Impedance Detection, Residual Current Detection
Surge Protection Level TYPE II(DC),TYPE II(AC)
Interface
LCD/LED Display LCD
Communication Interface WIFI,RS485
General Data
Operating Temperature Range(℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0~100%
Permissible Altitude 2000m
Noise(dB) ≤30
Ingress Protection(IP) Rating TYPE3R
Inverter Topology Non-Isolated (solar), Isolated (battery)
Over Voltage Category OVC II(DC),OVC IV(AC)
Cabinet size(WxHxD mm) 420×670×233 (Excluding Connectors and Brackets)
Weight(kg) 30
Type Of Cooling Intelligent Air Cooling
Warranty 5 Years / Up to 10 Years*
*Warranty period varies by installation country. Refer to the Warranty Policy for details.
Grid Regulation EN 50549,UNE 217002,NRS 097,IEEE 1547.1,SRD V2.0
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Cabinet dimensions exclude connectors and mounting brackets. The latest datasheet lists TYPE3R enclosure protection; confirm the supplied version and local installation requirements. Warranty availability depends on installation country and Deye policy.

Rear Construction and Mounting

The original manufacturer rear view helps identify the mounting layout. Keep service access and ventilation clearances available.

Deye SG01LP1-US original rear construction and mounting view

Controls and Connection Interfaces

The manufacturer overview identifies the LCD, operating controls, battery terminals, PV inputs and grid, load and generator connections. Use the exact manual for terminal identification and installation.

Deye SG01LP1-US manufacturer controls and connection ports overview

System Integration

The gallery architecture illustrates PV generation, battery storage, grid, backup loads and optional generator integration. It is a system overview; final cable sizing, protection, earthing and commissioning follow the installation manual.

Frequently Asked Questions

Is this a standard 230V single-phase inverter?

This product is designed for split-phase applications, with 120/240V and 60Hz ratings. Verify the exact supply, configuration and destination-country requirements before ordering.

Can it work with a 51.2V LiFePO4 battery?

51.2V is within the 40–60V operating range. Confirm battery BMS communication, firmware, charge/discharge current and usable capacity before pairing.

Are all power variants identical?

No. Battery current is 120A, 135A, 190A and 190A for 5, 6, 7.6 and 8kW respectively. PV string inputs are 1+1, 2+1, 2+2 and 2+2; passthrough is 40A for 5/6kW and 50A for 7.6/8kW.

How long can it supply backup power?

Runtime depends on usable battery energy, load demand, battery limits and conversion losses. The inverter kW rating does not determine backup duration.

Can multiple units operate together?

Deye specifies up to 16 compatible units in parallel. Check firmware, communication, battery design and the exact manufacturer parallel wiring instructions.

What information is needed for a quotation?

Send the required power rating, country, grid voltage, battery model and quantity. Solarayen will confirm a suitable configuration, model availability and warranty terms.

Downloads

Deye official datasheet (PDF)

Deye official installation manual (PDF)

Request a Quotation

Contact Solarayen for model availability, compatible battery options and project quotations.

Category

Leave a Message

Tell us what product you need and include the voltage, capacity, quantity or application if available. We will contact you as soon as possible.

Contact Form Demo